8
Rockwell Automation Publication 520-QS001A-EN-E - March 2014
PowerFlex 520-Series Adjustable Frequency AC Drive
PowerFlex 525 AC Drives. PowerFlex® 525 AC Drives feature an innovative, modular design to support fast and easy installation and configuration. This next generation of compact drives offers embedded EtherNet/IP™ communications, USB programming, and standard safety features. PowerFlex 523 AC Drives. PowerFlex® 523 AC Drives are cost-effective and ideal for standalone machines. These drives provide an innovative, modular design that supports fast and easy installation and configuration. In addition, they offer USB programming, application-specific configuration, and flexible mounting options.
Technical Specifications
PowerFlex 523 Specifications
Input/Output Ratings
- The Allen-Bradley® PowerFlex® 523 AC Drives supports fast and easy installation and configurations. In addition, the PowerFlex® 523 AC Drives offer USB programming, application-specific configuration and flexible mounting options. PowerFlex 523 AC Drives enhances system performance.
- View online Quick start manual for Allen-Bradley PowerFlex 523 Media Converter or simply click Download button to examine the Allen-Bradley PowerFlex 523 guidelines offline on your desktop.
Digital Control Inputs (Input Current = 6 mA)
Approvals
Output Frequency: 0..500 Hz (Programmable)
Efficiency: 97.5% (Typical)
Efficiency: 97.5% (Typical)
SRC (Source) Mode:
18..24V = ON
0..6V = OFF
0..6V = OFF
SNK (Sink) Mode:
0..6V = ON
18..24V = OFF
18..24V = OFF
Control Output
Analog Control Inputs
Fuses and Circuit Breakers
Programmable Output, Form C
Resistive Rating: 3.0 A @ 30V DC, 125V AC and 240V AC
Inductive Rating: 0.5 A @ 30V DC, 125V AC and 240V AC
Resistive Rating: 3.0 A @ 30V DC, 125V AC and 240V AC
Inductive Rating: 0.5 A @ 30V DC, 125V AC and 240V AC
4-20 mA Analog: 250
Ω
input impedance
0-10V DC Analog: 100 k
Ω
input impedance
External Pot: 1..10 k
Ω
, 2 W min.
Recommended Fuse Type:
UL Class CC, J, T or Type BS88; 600V (550V) or equivalent.
Recommended Circuit Breakers: HMCP or equivalent.
Protective Features
Motor Protection: I
2
t overload protection – 150% for 60 s, 200% for 3 s (Provides Class 10 protection)
Overcurrent: 200% hardware limit, 300% instantaneous fault
Over Voltage: 100..120V AC Input – Trip occurs @ 405V DC bus voltage (equivalent to 150V AC incoming line)
200..240V AC Input – Trip occurs @ 405V DC bus voltage (equivalent to 290V AC incoming line)
380..480V AC Input – Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
525..600V AC Input – Trip occurs @ 1005V DC bus voltage (equivalent to 711V AC incoming line)
380..480V AC Input – Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
525..600V AC Input – Trip occurs @ 1005V DC bus voltage (equivalent to 711V AC incoming line)
Under Voltage: 100..120V AC Input – Trip occurs @ 190V DC bus voltage (equivalent to 75V AC incoming line)
200..240V AC Input – Trip occurs @ 190V DC bus voltage (equivalent to 150V AC incoming line)
380..480V AC Input – Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
525..600V AC Input – If P038 = 3 “600V” trip occurs @ 487V DC bus voltage (344V AC incoming line);
380..480V AC Input – Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
525..600V AC Input – If P038 = 3 “600V” trip occurs @ 487V DC bus voltage (344V AC incoming line);
– If P038 = 2 “480V” trip occurs @ 390V DC bus voltage (275V AC incoming line)
Control Ride Through: Minimum ride through is 0.5 s - typical value 2 s
Faultless Power Ride Through: 100 ms
PowerFlex 525 Specifications
Input/Output Ratings
Approvals
Output Frequency: 0..500 Hz (Programmable)
Efficiency: 97.5% (Typical)
Efficiency: 97.5% (Typical)
Digital Control Inputs (Input Current = 6 mA)
Analog Control Inputs
Fuses and Circuit Breakers
SRC (Source) Mode:
18..24V = ON
0..6V = OFF
0..6V = OFF
SNK (Sink) Mode:
0..6V = ON
18..24V = OFF
18..24V = OFF
4-20 mA Analog: 250
Ω
input impedance
0-10V DC Analog: 100 k
Ω
input impedance
External Pot: 1..10 k
Ω
, 2 W min.
Recommended Fuse Type:
UL Class J, T or Type BS88; 600V (550V) or equivalent.
Recommended Circuit Breakers: HMCP or equivalent.
Control Output
Programmable Output, Form A and Form B
Resistive Rating: 3.0 A @ 30V DC, 125V AC and 240V AC
Inductive Rating: 0.5 A @ 30V DC, 125V AC and 240V AC
Resistive Rating: 3.0 A @ 30V DC, 125V AC and 240V AC
Inductive Rating: 0.5 A @ 30V DC, 125V AC and 240V AC
Opto Outputs
30V DC, 50 mA
Non-inductive
30V DC, 50 mA
Non-inductive
Analog Outputs (10-bit)
0-10V: 1 k
0-10V: 1 k
Ω
min.
4-20 mA: 525
Ω
max.
Protective Features
Motor Protection: I
2
t overload protection – 150% for 60 s, 200% for 3 s (Provides Class 10 protection)
Overcurrent: 200% hardware limit, 300% instantaneous fault
Over Voltage: 100..120V AC Input – Trip occurs @ 405V DC bus voltage (equivalent to 150V AC incoming line)
200..240V AC Input – Trip occurs @ 405V DC bus voltage (equivalent to 290V AC incoming line)
380..480V AC Input – Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
525..600V AC Input – Trip occurs @ 1005V DC bus voltage (equivalent to 711V AC incoming line)
380..480V AC Input – Trip occurs @ 810V DC bus voltage (equivalent to 575V AC incoming line)
525..600V AC Input – Trip occurs @ 1005V DC bus voltage (equivalent to 711V AC incoming line)
Under Voltage: 100..120V AC Input – Trip occurs @ 190V DC bus voltage (equivalent to 75V AC incoming line)
200..240V AC Input – Trip occurs @ 190V DC bus voltage (equivalent to 150V AC incoming line)
380..480V AC Input – Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
525..600V AC Input – If P038 = 3 “600V” trip occurs @ 487V DC bus voltage (344V AC incoming line);
380..480V AC Input – Trip occurs @ 390V DC bus voltage (equivalent to 275V AC incoming line)
525..600V AC Input – If P038 = 3 “600V” trip occurs @ 487V DC bus voltage (344V AC incoming line);
– If P038 = 2 “480V” trip occurs @ 390V DC bus voltage (275V AC incoming line)
Control Ride Through: Minimum ride through is 0.5 s – typical value 2 s
Faultless Power Ride Through: 100 ms
UL
®
LIS
TED 966X
IN
D CONT EQ
UL508C
UL
®
LIS
TED 966X
IN
D CO NT EQ
C
CSA 22.2
LV Directive 2006/95/EC: EN 61800-5-1
EMC Directive 2004/108/EC: EN 61800-3:2004
N223
AC156
KCC: Article 58-2 of Radio Waves Act, Clause 3
GOST-R: POCC US.ME92.H00040
GOST-R: POCC US.ME92.H00040
UL
®
LIS
TED 966X
IN
D CONT EQ
UL508C
UL
®
LIS
TED 966X
IN
D CO NT EQ
Allen Bradley Powerflex 523 Manual Downloads
C
CSA 22.2
LV Directive 2006/95/EC: EN 61800-5-1
EMC Directive 2004/108/EC: EN 61800-3:2004
N223
AC156
KCC: Article 58-2 of Radio Waves Act, Clause 3
GOST-R: POCC US.ME92.H00040
GOST-R: POCC US.ME92.H00040
TUV
Rheinland
.
.
Functional
Safety
Bauart geprüft
Type approved
II (2) G D
Advertising
This manual is related to the following products:
Popular Brands
Popular manuals
Advertising
Rockwell Automation Publication 520-QS001A-EN-E - March 2014
11
PowerFlex 520-Series Adjustable Frequency AC Drive
Control Terminal Block
PowerFlex 523 Control I/O Wiring Block Diagram
04
05
06
01
02
03
11
12
13
14
15
C1
C2
Digital Common
DigIn TermBlk 05/Pulse
DigIn TermBlk 06
Stop
Powerflex 523 Vfd Manual
(1)
DigIn TermBlk 02/
Start/Run FWD
(2)
DigIn TermBlk 03/
Direction/Run REV
R1
R2
Relay N.O.
Relay Common
+24V DC
+10V DC
0-10V Input
Analog Common
4-20mA Input
RJ45 Shield
Comm Common
+24V
+10V
Ab Powerflex 523 Pdf
Typical
SNK wiring
Typical
SRC wiring
R1
11
12
13
14
15
C1
C2
R2
R3
01
02
04
05
06
Pot must be
1..10 k ohm
2 W min.
SNK
D
igital In
D
igIn T
ermBlk
05
Se
l
J7
J8
Pulse In
Powerflex 523 Drive Manual
SRC
Digital
Input
SRC
SNK
R3
Powerflex 523 Parameter List
Relay N.C.
Powerflex 523 Manual
81
RS485
(DSI)
(1)
Powerflex 523 Programming Parameters
(2) Two wire control shown. For three wire control use a momentary input
on I/O Terminal 02 to command a start. Use a maintained input
for I/O Terminal 03 to change direction.
(3) Only one analog frequency source may be connected at a time. If more than one reference is connected at the same time, an undetermined frequency reference will result.
IMPORTANT
I/O Terminal 01 is always a stop input. The stopping mode is determined by the drive setting.
The drive is shipped with a jumper installed between I/O Terminals 01 and 11. Remove this jumper when using I/O
Terminal 01 as a stop or enable input.
Terminal 01 as a stop or enable input.